X-Ray Power |
N/A 90 kV10 mA900 W |
Detector Scan Rate |
N/A Up to 2800 lines/sec |
Standard Detector Resolution |
N/A 0.8 mm |
Detection Algorithms Available |
N/A Binary Contrast Gradient Groups Morphology |
Inspectable Belt Width at 50 Millimeter Height |
N/A 540 mm |
Maximum Inspectable Belt Width at 250 Millimeter Height |
N/A 400 mm |
Belt Speed Range |
N/A 10 to 60 m/min33 to 196 ft/min |
Multi-Lane Operation |
N/A Single lane or 8 lanes with separate reject gates |
Maximum Conveyable Product Weight |
N/A 40 kg88 lb |
Standard Line Height |
N/A 900 mm |
Standard Line Height Tolerance (±) |
N/A 100 mm |
System Length |
N/A 2.1 m82.7 in |
X-Ray Shielding |
N/A Lead Free, FDA Approved Curtains |
Safety/Security Features |
N/A All Doors have Magnetic Interlocks Emergency Stops Light-Emitting Diode (LED) X-Ray Imminent/On Lights Radiation Curtains X-Ray Power Key |
Human Machine Interface (HMI) |
N/A 15-inch Diagonal Touchscreen with Protective Cover |
Interface Languages Available1 | N/A Chinese English French German Hungarian Italian Korean Norwegian Polish Spanish |
Operating Temperature |
N/A 5 to 40 ºC+41 to +104 ºF |
Machine Cooling |
N/A External Water Chiller |
Non-Condensing Relative Humidity |
N/A 0 to 90 % |
Universal Serial Port (USB) Port2 | N/A 2.0 |
Network Port |
N/A Ethernet |
Machine Weight (Standard Model) |
N/A 1040 kg2290 lb |
Electrical Input Alternating Current (AC) Voltage |
N/A 190 to 240 V |
Electrical Input Frequency |
N/A 50 Hz60 Hz |
Electrical Input Phase |
N/A 1 |
Electrical Input Current |
N/A 16 A |
Radiation Safety Conformance3 | N/A Food and Drug Administration Code of Federal Regulations (FDA CFR) 21 Part 1020.40 |
Export and Safety |
N/A European Conformity (CE) Underwriters Laboratories (UL 508A) |
Intrusion Protection Rating4 | N/A Ingress Protection (IP65) |
Features |
N/A
All of the Xpert™ HD systems have the following features:
|